Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Daikin General: Water spilled on the floor

Updated · by Aurora Star Tech Inc.

Water spilled on the floor on a Daikin general: Water leaks out of the unit onto the floor.

Homeowner with a heating or cooling system problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: MCKB70YSAU

Common causes of water spilled on the floor

  • Unit was tilted, so water in the tank or tray spilled out
  • Water scale buildup on the humidifying filters causes leakage
  • Float is stuck, causing leakage
  • Dust caught in the water tank valve, so the valve does not close
  • Water scale around the water tank valve, so the valve does not close

How to fix water spilled on the floor: step by step

  1. Before moving the unit, turn off the power and empty the water tank and humidifying tray.
  2. Clean water scale off the humidifying filters (see p. 28-29).
  3. Clean the float if it is stuck (see p. 28).
  4. Clean dust out of the water tank valve (see p. 27).
  5. Clean water scale from the area around the water tank valve (see p. 27).
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Daikin General codes

Source: Daikin MCKB70YSAU installation & operation manual, p. 40. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service