Daikin General: Installing the carbon filter
Installing the carbon filter on a Daikin general: Remove the water tank, humidifying tray and filter fixing unit, fit the carbon filter onto the dust collection filter, then refit the parts in order.
Applies to: Carbon filter (black), filter fixing unit
How to fix installing the carbon filter: step by step
- Take out the water tank by pressing the lever and releasing the side lock.
- Remove the humidifying tray by lifting it slightly and pulling it out.
- Slide the fixing tab to unlock the filter fixing unit, lift its grip and pull it out.
- Take the carbon filter out of its bag. It has no front or back. Wear gloves, and dispose of the bag and desiccant under local rules.
- Push the short side of the carbon filter fully into the unit and lay it on the dust collection filter. Turn it if it does not fit.
- Refit the filter fixing unit and slide the fixing tab to lock it.
- Refit the humidifying tray, then the water tank.
If the unit shows an error code, look it up: Daikin General codes
Source: Daikin MCKB70YSAU installation & operation manual, p. 13, p. 14, p. 15. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.