Daikin General: Cleaning the sensor probe
Cleaning the sensor probe on a Daikin general: Dirt inside the two air passageways of the sensor probe can make the particulate readings inaccurate. Only a qualified electrician or HVAC technician should do this. If you are not qualified, contact the HVAC dealer.
Applies to: DSEN-HAQA Daikin One Home Air Monitor
Common causes of cleaning the sensor probe
- Particulate buildup on the internal surfaces of the sensor probe passageways
- Visible debris collected inside the probe
How to fix cleaning the sensor probe: step by step
- Remove power from the sensor probe by disconnecting the 24V supply wire from its transformer.
- Pull the sensor probe out of the ductwork and leave the mounting plate in place.
- Inspect the two passageways in the probe for visible particulate buildup.
- If nothing is visible, reinsert the probe into the mounting plate until it clicks. Do not push it past the click.
- If debris is visible, wet a cotton swab slightly with isopropyl or rubbing alcohol and gently wipe the internal surfaces of the probe. Then reinsert the probe until it clicks, without pushing past the click.
- Reconnect the 24V power to the sensor probe.
- Confirm the probe LED is solid blue, not flashing. Solid blue means the device is back online and operating.
If the unit shows an error code, look it up: Daikin General codes
Source: Daikin One Home Air Monitor installation manual (IO-DSEN-HAQA), p. 4. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.