Daikin General: Clean the dust/particle sensor

Updated · by Aurora Star Tech Inc.

Clean the dust/particle sensor on a Daikin general: Clean about once every 3 months. The sensor lens and air intake must be kept clear for accurate readings.

Homeowner with a heating or cooling system problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Dust/particle sensor

How to fix clean the dust/particle sensor: step by step

  1. Unplug the unit.
  2. Remove the pre-filter from the right side.
  3. Remove the cover of the sensor air intake by unhooking it and pulling toward you.
  4. Vacuum dust from the area with a crevice tool.
  5. Lightly rub the inside left side with a dry cotton swab, then vacuum again.
  6. Clean the lens area if dust is present.
  7. Refit the cover securely, otherwise a malfunction may result.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Daikin General codes

Source: Daikin MCKB70YSAU installation & operation manual, p. 25. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.