Thermostat shows communication error or equipment not recognized on a Daikin furnace: The thermostat reports a communication error or does not recognize the equipment after installation.
Applies to: Daikin One+ with communicating indoor or outdoor units
Common causes of thermostat shows communication error or equipment not recognized
- Thermostat terminals 1, 2, C, R are wired incorrectly to the indoor or outdoor unit.
- Data line voltage is wrong between Data 1 and Data 2.
- Connector pairing on the indoor or outdoor unit does not match the thermostat terminals.
How to fix thermostat shows communication error or equipment not recognized: step by step
- Check the wiring against the terminal pairing for the system type.
- Check voltage between Data 1 and Data 2, expecting about 0.6 VDC.
- Check the 9 pin or 7 pin connector position on the indoor or outdoor unit board.
- Check the voltage again after wiring is complete.
If the unit shows an error code, look it up: Daikin Furnace codes
Source: Daikin One+ installation & commissioning, p. 15-16. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.