Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Daikin Air Conditioner: Remove thermistors and insulation tube on AC models

Updated · by Aurora Star Tech Inc.

Remove thermistors and insulation tube on AC models on a Daikin air conditioner: AC 1.5 to 3.0 ton units. Remove the outdoor air, outdoor coil and pipe thermistors, detach the OL relay and HPS connectors, and remove the insulation tube.

Homeowner with a air conditioner problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: 1.5 to 3.0 ton AC models

How to fix remove thermistors and insulation tube on ac models: step by step

  1. Remove the outdoor air thermistor and the outdoor coil thermistor.
  2. Remove the suction pipe, discharge pipe and liquid pipe thermistors.
  3. Detach the OL relay connector and the HPS connectors.
  4. Cut the 2 clamps and remove the insulation tube from the suction pipe thermistor.
  5. When reassembling, keep the lead wires from touching the edges.
  6. When reassembling, face the slit in the insulation tube away from the suction pipe thermistor.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Daikin Air Conditioner codes

Source: Daikin sm-sius612209ea service instructions, pp. 92-93. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service