Daikin Air Conditioner: Remove compressor, AC models 3.5 to 5.0 ton
Remove compressor, AC models 3.5 to 5.0 ton on a Daikin air conditioner: Air conditioner models only. Work from the stop valve plate and sound blankets down to the compressor mounting nuts.
Applies to: DX6VS / DZ6VS air conditioner outdoor units, 3.5 to 5.0 ton
How to fix remove compressor, ac models 3.5 to 5.0 ton: step by step
- Remove the 6 screws and take off the stop valve mounting plate. The circled screws are 3-class hex head tapping screws (M5 x 16); reuse the same screws when reassembling.
- If a conduit tube is connected to the stop valve plate, remove it.
- Remove the top sound blanket, then the body sound blanket.
- Remove the terminal cover. The 5.0 ton model is shown as the representative drawing.
- Disconnect the compressor lead wires. Wiring differs by model: U is red, V is yellow, W is blue. Reconnect them exactly as shown when reassembling.
- Remove the OL. When reassembling, fit the retainer as described in the manual and route the OL lead wire through the harness path.
- Protect the area from the brazing flame as with the other procedures.
- Heat the brazed compressor piping joints and disconnect them.
- Remove the 2 nuts that secure the compressor.
If the unit shows an error code, look it up: Daikin Air Conditioner codes
Source: Daikin DX6VS/DZ6VS service instructions SiUS612209EA, pp. 121 to 123. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.