Daikin Air Conditioner: Outdoor unit wiring removal (AC models)
Outdoor unit wiring removal (AC models) on a Daikin air conditioner: Disconnects compressor, pressure switch and sensor wiring on AC models.
Applies to: 3.5 to 5.0 ton AC models
How to fix outdoor unit wiring removal (ac models): step by step
- Disconnect the PS connector (X17A).
- Disconnect the compressor connectors (U, V, W) and release the lead wires from the hooks.
- Remove the outdoor air thermistor.
- Remove the outdoor coil thermistor.
- Remove the insulation tube and suction pipe thermistor as described for the HP unit, using the same slit alignment on reassembly.
- Remove the discharge pipe thermistor, liquid pipe thermistor and ground wire.
- Detach the OL relay connector.
If the unit shows an error code, look it up: Daikin Air Conditioner codes
Source: Daikin SiUS612209EB service instructions, p. 114-115. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.