Carrier Air Conditioner: Upflow coil installation
Upflow coil installation on a Carrier air conditioner: Set the cased coil on the furnace discharge opening and check that it is level.
Applies to: Upflow installations
How to fix upflow coil installation: step by step
- Set the coil on the upflow furnace discharge air opening.
- Check that the coil is level for proper condensate drainage. Do not tip it toward the drain.
- The casing does not need to be fastened to the furnace.
- If a wider coil sits on a narrower furnace, build a field-fabricated adapter.
- Keep at least 4 in. clearance as shown in the figures on the coil and furnace.
- If the coil is in an unconditioned space, wrap a 6 in. wide insulation strip around the casing and supply duct contact point.
If the unit shows an error code, look it up: Carrier Air Conditioner codes
Source: DLFULA Installation Instructions, pp. 10, 12. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.