Carrier Air Conditioner: Secondary condensate protection above living space
Secondary condensate protection above living space on a Carrier air conditioner: If the unit sits in or above a living space, protect against overflow water damage.
Applies to: Units in or above living spaces
Common causes of secondary condensate protection above living space
- Condensate overflow from the primary pan can cause water damage.
How to fix secondary condensate protection above living space: step by step
- Install a field-supplied external condensate pan under the whole unit, with a secondary drain line and trap run into it.
- Drain the external pan to a visible location.
- Alternatively, run a separate 3/4 in. (19 mm) secondary condensate line with trap where local code allows.
- Install a float switch to shut the unit off if water in the secondary pan rises too high.
- Tell the owner that the unit needs service if water flows from the secondary drain.
If the unit shows an error code, look it up: Carrier Air Conditioner codes
Source: DLFULA Installation Instructions, pp. 15-16. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.