Bosch Boiler: Force minimum or maximum output for 15 minutes (function 2.F)

Updated · by Aurora Star Tech Inc.

Force minimum or maximum output for 15 minutes (function 2.F) on a Bosch boiler: Temporary test mode: 00 normal, 01 minimum output for 15 minutes, 02 maximum output for 15 minutes. The boiler returns to normal after 15 minutes or when aborted.

Homeowner with a boiler problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Greenstar ZBR/ZWB 21-42-3A wall-hung boilers and ZWB 28-42-3A combis

How to fix force minimum or maximum output for 15 minutes (function 2.f): step by step

  1. Open service functions with the service button and scroll with key pad lock / ECO
  2. Select 2.F, choose 01 or 02, save
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Bosch Boiler codes

Models

ZBR21-3AZBR28-3AZBR35-3AZBR42-3A

Source: Bosch Greenstar wall ZBR-ZWB 21-42-3A service 6721853955 (2025-11) (same content in combi service 6721853953), 11.3 Description of the service functions pp.59-64. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.