AFG burner: annual service checklist on a Beckett boiler: What to do on the yearly service of an AFG burner. Service once a year, more often in dusty places.
Applies to: Beckett AF/AFG oil burners (0.40-3.00 GPH) on Weil-McLain WGO, WTGO, SGO and Ultra Oil boilers
Common causes of afg burner: annual service checklist
- Dirty filter, strainer or nozzle
- Worn electrodes or igniter contacts
- Dirty cad cell lens or blower wheel
- Sooted flue passages
How to fix afg burner: annual service checklist: step by step
- Turn off all power to the burner first (there may be more than one switch).
- Replace the oil line filter. Clean or replace the pump strainer and its gasket/O-ring.
- Check the oil lines for leaks, water and sludge.
- Replace the nozzle with the exact one the boiler maker specifies.
- Clean and check electrodes. Replace if cracked or tips are rounded. Re-check electrode settings.
- Clean or replace corroded igniter contacts. Clean the cad cell lens.
- Clean the head, air tube, blower wheel, air inlet and static plate. Replace damaged gaskets.
- Check motor amps (not over nameplate), wiring, pump pressure and cut-off, primary lockout timing and ignition.
- Clean the flue passages and flue pipe. Check the chimney for soot.
- Set combustion with instruments and write down the results (myTechnician app with the 7565 control).
If the unit shows an error code, look it up: Beckett Boiler codes
Source: Beckett AF/AFG Burner Manual for Weil-McLain WGO/WTGO/SGO boilers (550-143-079/1224), Perform regular maintenance, p.16. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.