Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Trane Error Code Starting Soon: Starting Soon (General)

Updated · by Aurora Star Tech Inc.

Trane error code Starting Soon on a general means: Starting Soon. It is also called Trane diagnostic code Starting Soon.

Low severityGeneralXR202 · TCONT202

Homeowner? What Trane code Starting Soon means for you

Usually minor Your heating or cooling system is reporting: Starting Soon. This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Make sure the unit has power: its on/off switch (often looks like a light switch near the unit) is ON and the breaker in the electrical panel is not tripped.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Trane error code Starting Soon mean?

Compressor lockout is active. The compressor will start after up to a 5 minute delay.

Applies to: Trane XR202 / TCONT202

Common causes of Trane code Starting Soon

  • Compressor lockout option On (installer item 50)
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Other Trane General codes

CodeMeaning
HoldHold active
On/Off light flashing greenStart-up delay after power restored
On/Off light solid greenHumidifier on
ReplaceBattery replacement indicator
Service light flashing redCanister at end of life
Service light solid redOver-current fault, humidifier shut down
Steam light solid greenMaking steam, normal
Steam light solid yellowNot making rated steam output

All Trane General error codes →

Trane code Starting Soon: homeowner questions

What does Trane code Starting Soon mean?

Starting Soon. Compressor lockout is active. The compressor will start after up to a 5 minute delay.

Is it safe to keep using my heating or cooling system with code Starting Soon?

Usually yes. Code Starting Soon is normally minor, but if it keeps coming back have it checked.

Can I reset Trane code Starting Soon myself?

You can try one reset (power off for 30 seconds, then on). If Trane code Starting Soon comes back, the cause is still there and a licensed technician should check it.

Who can fix Trane code Starting Soon near me?

Aurora Star Tech Inc. repairs Trane heating or cooling systems in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Troubleshooting guides

Source: 18-HD51D1-1C-EN Installation and User Guide, p. 9. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977