Rheem Heat Pump Outdoor unit clearances
Rheem Heat Pump Outdoor unit clearances: reference table for the heat pump (Rheem/Ruud PRL-JEC heat pump (Comfort Control2 ICC) series): a quick-reference table with notes.
Rheem Heat Pump Outdoor unit clearances table
| Location | Minimum |
|---|---|
| Above unit (fan discharge) | 60 in. [1524 mm] |
| Coil air inlets (3 sides) | 6 in. [152 mm] |
| Service access side | 24 in. [610 mm] |
| Between two units (grille sides aligned) | 12 in. total (6 in. per unit) |
How to use the Rheem Heat Pump Outdoor unit clearances table
Find your exact model in the first column and read across the row. Values in the Rheem Heat Pump Outdoor unit clearances table are a summary for quick reference; the rating plate on the unit and the manufacturer's manual for your model always decide. If your model is not listed, or a value looks different from what you see on the unit, check the manual before changing anything.
Notes
- Do not reduce the 60 in. discharge or 24 in. service clearances.
- Inlet clearances under 6 in. reduce capacity and efficiency.
- Cabinet: 33 in. high, 44-3/4 in. long, 31-1/2 in. wide (all sizes).
Applies to: RPRL-024JEC, RPRL-036JEC, RPRL-048JEC, RPRL-060JEC (also Ruud UPRL)
Rheem models this applies to
RPRL-024JECRPRL-036JECRPRL-048JECRPRL-060JEC
Source: Rheem/Ruud (-)PRL-JEC Installation Instructions 92-20522-63-06, Figure 1 and 3.3-3.4, PDF p.9 (printed p.6); PDF p.11 (printed p.8). Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.