Glow Brand Boiler Maintenance intervals
Glow Brand Boiler Maintenance intervals: reference table for the boiler (Glow B85/B120/B160 series): a quick-reference table with notes.
Glow Brand Boiler Maintenance intervals table
| Item | When |
|---|---|
| Annual inspection by a technician | Every year (warranty) |
| Relief valve try-lever test | Annually |
| LWCO test | Annually |
| Condensate trap clean | Annually (14.3) |
| Heat exchanger combustion-side wash | Annually or when combustion drifts (14.4) |
| Burner door silicone gasket | Replace if damaged or after 2 years |
| Service reminder | 2.203 on, interval 2.204 (default 1000 days) |
How to use the Glow Brand Boiler Maintenance intervals table
Find your exact model in the first column and read across the row. Values in the Glow Brand Boiler Maintenance intervals table are a summary for quick reference; the rating plate on the unit and the manufacturer's manual for your model always decide. If your model is not listed, or a value looks different from what you see on the unit, check the manual before changing anything.
Notes
- Operating pressure should sit 5 psi under the relief valve rating (max 25 psig on a 30 psi valve); water never above 180 F.
Applies to: B85, B120, B160 (NG and LP)
Glow Brand models this applies to
Glow Brand Boiler error codes →
Source: Glow Brand B85/B120/B160 Installation & Operation Manual V20231025, 14.1-14.2 p.69. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.