Icon
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Gree Error Code E5: Overcurrent protection (whole unit) (Heat Pump)

Updated · by Aurora Star Tech Inc.

Gree error code E5 on a heat pump means: Overcurrent protection (whole unit). It is also called Gree diagnostic code E5.

High severityHeat PumpGree Sapphire · Gree Livo GEN4 · Gree Vireo GEN3 · Gree Multi21+

Homeowner? What Gree code E5 means for you

Call a technician Your heat pump is reporting: Overcurrent protection (whole unit). The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Gree error code E5 mean?

Total current drawn by the outdoor unit went above its limit, so the compressor and outdoor fan stop.

Applies to: Gree Sapphire 9-24k (SAP..HP230V1A), Livo GEN4 30-36k (4LIV..HP230V1A), Vireo GEN3 9-24k (3VIR..HP115/230V1A), Multi21+ 18-24k multi-zone (MULTI..HP230V1CO)

Common causes of Gree code E5

  • Supply voltage unstable or too low under load
  • Dirty coils or blocked airflow
  • Fan motor slow or stopped

A technician checks these and 3 other possible causes on site before replacing any part.

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Gree models that use code E5

3VIR09HP115V1A3VIR09HP230V1A3VIR12HP115V1A3VIR12HP230V1A3VIR18HP230V1A3VIR24HP230V1A4LIV30HP230V1AH4LIV36HP230V1AHMULTI18HP230V1COMULTI24HP230V1COSAP09HP230V1AHSAP12HP230V1AHSAP18HP230V1AHSAP24HP230V1AH

Other Gree Heat Pump codes

CodeMeaning
dnWrong interconnect wiring or EEV fault
E0Outdoor unit fault (shown with another code)
E1High pressure protection
E2Indoor coil freeze protection (status)
E3Low pressure protection
E4Compressor discharge temperature too high
E6Indoor/outdoor communication fault
E7Mode conflict between indoor units (status)
E8High temperature / overload protection
E9Cold air prevention (status)
EdDrive IPM low temperature protection
EEEEPROM / memory chip fault

All Gree Heat Pump error codes →

Gree code E5: homeowner questions

What does Gree code E5 mean?

Overcurrent protection (whole unit). Total current drawn by the outdoor unit went above its limit, so the compressor and outdoor fan stop.

Is it safe to keep using my heat pump with code E5?

It depends on the cause. The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Gree code E5 myself?

You can try one reset (power off for 30 seconds, then on). If Gree code E5 comes back, the cause is still there and a licensed technician should check it.

Who can fix Gree code E5 near me?

Aurora Star Tech Inc. repairs Gree heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Gree Sapphire 9-12k (SAP09-12HP230V1A) service.pdf - section 9.1 Error Code List / 9.2 Procedure of Troubleshooting; Gree Sapphire 18-24k (SAP18-24HP230V1A) service.pdf - section 9.1 Error Code List / 9.2 Procedure of Troubleshooting; Gree Livo GEN4 30-36k (4LIV30-36HP230V1A) service.pdf - section 9.1 Error Code List / 9.2 Procedure of Troubleshooting; Gree Vireo GEN3 9-24k (3VIR..HP115-230V1A) service GREE_VIREOGEN3_SERVICE_090921.pdf - section 9.1 Error Code List / 9.2 Procedure of Troubleshooting; Gree Multi21+ multi-zone 18-24k (MULTI18-24HP230V1CO) service.pdf - section 9.1 Malfunction status sheet / 9.2 Malfunction Checking and Elimination. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977