Fujitsu Error Code Outdoor LED1 19 flashes: High compressor temperature (outdoor board LED) (Heat Pump)

Updated · by Aurora Star Tech Inc.

Fujitsu error code Outdoor LED1 19 flashes on a heat pump means: High compressor temperature (outdoor board LED). It is also called Fujitsu diagnostic code Outdoor LED1 19 flashes.

High severityHeat PumpFujitsu multi-zone outdoor 18/24 type

Homeowner? What Fujitsu code Outdoor LED1 19 flashes means for you

Call a technician Your heat pump is reporting: High compressor temperature (outdoor board LED). The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Fujitsu error code Outdoor LED1 19 flashes mean?

Multi-zone 18/24 outdoor board: LED1 flashes 19 times while the other LEDs stay off. Same fault family as indoor code A3. The LEDs sit on the back side of the board and are seen through a hole.

Applies to: Fujitsu 18 type (2-zone) and 24 type (3-zone) multi outdoor units

Common causes of Fujitsu code Outdoor LED1 19 flashes

  • Low charge
  • Restriction
  • Poor airflow
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Other Fujitsu Heat Pump codes

CodeMeaning
Outdoor LED1 12 flashesOvercurrent trip detection (outdoor board LED)
Outdoor LED1 13 flashesCompressor rotor position detection error (outdoor board LED)
Outdoor LED1 14 flashesTrip terminal L error (outdoor board LED)
Outdoor LED1 15 flashesOutdoor fan motor error (outdoor board LED)
Outdoor LED1 17 flashesOutdoor PCB micro communication error (outdoor board LED)
Outdoor LED1 18 flashesHigh discharge temperature (outdoor board LED)
Outdoor LED1 20 flashes4-way valve error (outdoor board LED)
Outdoor LED1 21 flashesOutdoor PCB model information error (outdoor board LED)
Outdoor LED1 22 flashesActive filter / PFC circuit error (outdoor board LED)
Outdoor LED2 1 flashSerial comms error, outdoor to indoor unit B (outdoor board LED)
Outdoor LED2 5 flashes2-way valve sensor error, unit B (outdoor board LED)
Outdoor LED2 6 flashes3-way valve sensor error, unit B (outdoor board LED)

All Fujitsu Heat Pump error codes →

Fujitsu code Outdoor LED1 19 flashes: homeowner questions

What does Fujitsu code Outdoor LED1 19 flashes mean?

High compressor temperature (outdoor board LED). Multi-zone 18/24 outdoor board: LED1 flashes 19 times while the other LEDs stay off. Same fault family as indoor code A3. The LEDs sit on the back side of the board and are seen through a hole.

Is it safe to keep using my heat pump with code Outdoor LED1 19 flashes?

It depends on the cause. The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Fujitsu code Outdoor LED1 19 flashes myself?

You can try one reset (power off for 30 seconds, then on). If Fujitsu code Outdoor LED1 19 flashes comes back, the cause is still there and a licensed technician should check it.

Who can fix Fujitsu code Outdoor LED1 19 flashes near me?

Aurora Star Tech Inc. repairs Fujitsu heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Source: Fujitsu Outdoor unit 18-24 type (North American trilingual) installation P-N 9374747160.pdf - section 8.2 Outdoor unit LED. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977