Icon
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Fujitsu Error Code Error memory recall: Show the stored error on the indoor lamps (Heat Pump)

Updated · by Aurora Star Tech Inc.

Fujitsu error code Error memory recall on a heat pump means: Show the stored error on the indoor lamps. It is also called Fujitsu diagnostic code Error memory recall.

Low severityHeat PumpFujitsu wall-mounted KMCG (ASEH-AOEH 07-14)

Homeowner? What Fujitsu code Error memory recall means for you

Usually minor Your heat pump is reporting: Show the stored error on the indoor lamps. This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Fujitsu error code Error memory recall mean?

The indoor unit stores the last error in memory even through a power cut, and a newer error replaces the older one. The stored error can be read on the OPERATION, TIMER and ECONOMY lamps during the 3-minute start-up wait (2 minutes 20 seconds after power is applied). If nothing is stored the unit shows its TEST RUN display instead. The memory clears after 2 hours of fault-free running or by pressing MANUAL AUTO while it is displayed.

Applies to: Fujitsu ductless heat pumps: Fujitsu wall-mounted KMCG (ASEH07-14KMCG / AOEH07-14KMCG)

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Other Fujitsu Heat Pump codes

CodeMeaning
994-way valve error
A1High discharge temperature
A3High compressor temperature
A4High pressure error
A5Low pressure error
Custom code A/B/C/DWireless remote custom code display
J1VRF branch box error
J2Branch box error (flexible multi)
MANUAL AUTO 10 sStart test run / forced cooling from the indoor unit
OPERATION + TIMER lamps flash togetherTest run / forced cooling running
Outdoor LED1 1 flashSerial comms error, outdoor to indoor unit A (outdoor board LED)
Outdoor LED1 2 flashesDischarge temperature sensor error (outdoor board LED)

All Fujitsu Heat Pump error codes →

Fujitsu code Error memory recall: homeowner questions

What does Fujitsu code Error memory recall mean?

Show the stored error on the indoor lamps. The indoor unit stores the last error in memory even through a power cut, and a newer error replaces the older one. The stored error can be read on the OPERATION, TIMER and ECONOMY lamps during the 3-minute start-up wait (2 minutes 20…

Is it safe to keep using my heat pump with code Error memory recall?

Usually yes. Code Error memory recall is normally minor, but if it keeps coming back have it checked.

Can I reset Fujitsu code Error memory recall myself?

You can try one reset (power off for 30 seconds, then on). If Fujitsu code Error memory recall comes back, the cause is still there and a licensed technician should check it.

Who can fix Fujitsu code Error memory recall near me?

Aurora Star Tech Inc. repairs Fujitsu heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Fujitsu Wall-mounted KMCG (ASEH-AOEH 07-14) - Fujitsu UK; same error-code scheme as NA ASU-AOU units service S.pdf - section 03 Troubleshooting, 1-1 and 1-2 error memory. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service