Gree Error Code 8°C: 8 degC heating mode active (Heat Pump)
Gree error code 8°C on a heat pump means: 8 degC heating mode active. It is also called Gree diagnostic code 8°C.
Homeowner? What Gree code 8°C means for you
Usually minor Your heat pump is reporting: 8 degC heating mode active. This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.
Safe things you can check yourself
- Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
- Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
- Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
- In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
- Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.
Call (647) 657-2977Book a service call
Licensed technicians serving Vaughan, Toronto and the GTA.
What does Gree error code 8°C mean?
In heating mode, pressing TEMP and CLOCK together shows a heating icon and 8°C (46°F with Fahrenheit display) on the remote. The unit then holds an 8°C set point with the fan fixed on auto. Sleep and this mode cancel each other. Not a fault.
Applies to: Gree Sapphire 9-24k (SAP..HP230V1A); Livo GEN4 30-36k (4LIV..HP230V1A); Vireo GEN3 9-24k (3VIR..HP115/230V1A)
Gree models that use code 8°C
3VIR09HP115V1A3VIR09HP230V1A3VIR12HP115V1A3VIR12HP230V1A3VIR18HP230V1A3VIR24HP230V1A4LIV30HP230V1AH4LIV36HP230V1AHSAP09HP230V1AHSAP12HP230V1AHSAP18HP230V1AHSAP24HP230V1AH
Other Gree Heat Pump codes
All Gree Heat Pump error codes →
Gree code 8°C: homeowner questions
What does Gree code 8°C mean?
8 degC heating mode active. In heating mode, pressing TEMP and CLOCK together shows a heating icon and 8°C (46°F with Fahrenheit display) on the remote. The unit then holds an 8°C set point with the fan fixed on auto. Sleep and this mode cancel each other. Not a…
Is it safe to keep using my heat pump with code 8°C?
Usually yes. Code 8°C is normally minor, but if it keeps coming back have it checked.
Can I reset Gree code 8°C myself?
You can try one reset (power off for 30 seconds, then on). If Gree code 8°C comes back, the cause is still there and a licensed technician should check it.
Who can fix Gree code 8°C near me?
Aurora Star Tech Inc. repairs Gree heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air
Troubleshooting guides
- 2 flashes: HPS open ≥6 s; 3: discharge >263°F; 4: discharge <90°F after 1 h; 5: defrost failure; 6: discharge sensor short; 7: outdoor sensor open/short; 9: bonnet sensor fail All brands · Heat Pump
- Auxiliary heat indicator light is on All brands · Heat Pump
- Cleaning the outdoor unit finish All brands · Heat Pump
- Excess ice on outdoor coil All brands · Heat Pump
- Extremely high head pressure in heating (dual fuel) All brands · Heat Pump
- Insufficient heat in cold weather All brands · Heat Pump
- Liquid slugging / compressor damage in heating All brands · Heat Pump
- No mode change / wrong mode All brands · Heat Pump
Source: Gree Sapphire 9-12k (SAP09-12HP230V1A) service.pdf - section 6.1 remote controller, combination buttons; Gree Sapphire 18-24k (SAP18-24HP230V1A) service.pdf - section 6.1 remote controller, combination buttons; Gree Livo GEN4 30-36k (4LIV30-36HP230V1A) service.pdf - section 6.1 function introduction for combination buttons; Gree Vireo GEN3 9-24k (3VIR..HP115-230V1A) service GREE_VIREOGEN3_SERVICE_090921.pdf - section 6.1 function introduction for combination buttons. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.