Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Bosch Error Code Open Taps: Open Taps message during auto adjust (Tankless)

Updated · by Aurora Star Tech Inc.

Bosch error code Open Taps on a tankless water heater means: Open Taps message during auto adjust. It is also called Bosch diagnostic code Open Taps.

Low severityTankless Water HeaterBosch Greentherm T9800 SE · Bosch Greentherm T9900 SE

Homeowner? What Bosch code Open Taps means for you

Usually minor Your tankless water heater is reporting: Open Taps message during auto adjust. This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.

Safe things you can check yourself

  • Check that gas reaches the house: other gas appliances work, or the propane tank is not empty.
  • Make sure the heater is plugged in and its breaker is on. In winter, keep the power on: it protects the unit from freezing.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the hot and cold water valves under the heater are fully open.
  • If you have a remote controller, turn it off and on once. If the code comes back, call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Bosch error code Open Taps mean?

During the automatic gas and air adjustment (UC Auto Adjust) the display shows Open Taps when more water flow is needed. Open more hot water taps (a tub and two sinks are usually enough) and let the process continue. It starts about 5 minutes into the adjustment and a green check mark shows when it finishes.

Applies to: Greentherm T9800 SE 160/199 and T9900 SE 160/199 tankless water heaters

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Bosch models that use code Open Taps

Greentherm T9800 SE 160Greentherm T9800 SE 199Greentherm T9800 SEC 199Greentherm T9900 i 199Greentherm T9900 SE 160Greentherm T9900 SE 199

Other Bosch Tankless codes

CodeMeaning
F9Gas valve driver fault
FAGas leak in the gas path
FCTouch key held over 20 seconds
FHFH failure history
HSHS about
ODOD operation data
P4P4 Information menu
P9P9 purge menu
PAPA water actuator (valve calibration)
PEPE appliance type (read-only data)
SASA settings menu
Setpoint displaySet temperature shown on touch display

All Bosch Tankless Water Heater error codes →

Bosch code Open Taps: homeowner questions

What does Bosch code Open Taps mean?

Open Taps message during auto adjust. During the automatic gas and air adjustment (UC Auto Adjust) the display shows Open Taps when more water flow is needed. Open more hot water taps (a tub and two sinks are usually enough) and let the process continue. It starts about 5…

Is it safe to keep using my tankless water heater with code Open Taps?

Usually yes. Code Open Taps is normally minor, but if it keeps coming back have it checked.

Can I reset Bosch code Open Taps myself?

You can try one reset (power off for 30 seconds, then on). If Bosch code Open Taps comes back, the cause is still there and a licensed technician should check it.

Who can fix Bosch code Open Taps near me?

Aurora Star Tech Inc. repairs Bosch tankless water heaters in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Tankless Water Heater No Hot Water: What to Check

Troubleshooting guides

Source: Bosch Greentherm T9800 SE 160-199 installation 6720816815 (06.2023), 8.11.1 Automatic Gas and Air adjustment p.60-61; T9900 SE 160-199 installation 6 720 813 635 (2024-06) same section. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.