Icon
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Bosch Error Code AC: AC consumption (Tankless)

Updated · by Aurora Star Tech Inc.

Bosch error code AC on a tankless water heater means: AC consumption. It is also called Bosch diagnostic code AC.

Low severityTankless Water HeaterBosch Greentherm T9800 SE · Bosch Greentherm T9900 SE

Homeowner? What Bosch code AC means for you

Usually minor Your tankless water heater is reporting: AC consumption. This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.

Safe things you can check yourself

  • Check that gas reaches the house: other gas appliances work, or the propane tank is not empty.
  • Make sure the heater is plugged in and its breaker is on. In winter, keep the power on: it protects the unit from freezing.
  • Outside, make sure the intake and exhaust pipes or vent cap are not blocked by snow, ice, leaves or a nest.
  • Check that the hot and cold water valves under the heater are fully open.
  • If you have a remote controller, turn it off and on once. If the code comes back, call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Bosch error code AC mean?

Gives a rough gas and water use figure for each of the last 5 runs that lasted over a minute. It is an estimate for comparison only and not for billing.

Applies to: Greentherm T9800 SE 160/199 and T9900 SE 160/199 tankless water heaters

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Bosch models that use code AC

Greentherm T9800 SE 160Greentherm T9800 SE 199Greentherm T9800 SEC 199Greentherm T9900 i 199Greentherm T9900 SE 160Greentherm T9900 SE 199

Other Bosch Tankless codes

CodeMeaning
A5Condensing unit flue temperature sensor fault
A6Inlet cold water temperature sensor fault
A7Heat exchanger hot water temperature sensor fault
A8Outlet hot water temperature sensor fault
A9Output power too low
AAFlue gas temperature too high, power limited
ADPower derate warning
AUAU technical settings (service mode)
BBFan calibration after missed ignitions
BCRepeated fan calibration with similar values
Burner symbolBurner status symbol - burner on
C1Flue blockage at start-up

All Bosch Tankless Water Heater error codes →

Bosch code AC: homeowner questions

What does Bosch code AC mean?

AC consumption. Gives a rough gas and water use figure for each of the last 5 runs that lasted over a minute. It is an estimate for comparison only and not for billing.

Is it safe to keep using my tankless water heater with code AC?

Usually yes. Code AC is normally minor, but if it keeps coming back have it checked.

Can I reset Bosch code AC myself?

You can try one reset (power off for 30 seconds, then on). If Bosch code AC comes back, the cause is still there and a licensed technician should check it.

Who can fix Bosch code AC near me?

Aurora Star Tech Inc. repairs Bosch tankless water heaters in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: Tankless Water Heater No Hot Water: What to Check

Troubleshooting guides

Source: Bosch Greentherm T9800 SE 160-199 installation 6720816815 (06.2023), 6.5 Information / Adjustments menu pp.47-48; T9900 SE 160-199 installation 6 720 813 635 (2024-06) same section. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977