Trane Heat Pump Outdoor unit placement
Trane Heat Pump Outdoor unit placement: reference table for the heat pump (Trane 5TWR7 series): a quick-reference table with notes.
Trane Heat Pump Outdoor unit placement table
| Item | Value |
|---|---|
| Above unit | 5 ft clear |
| Service side | 3 ft |
| Walls / shrubs | 12 in. min |
| Pad | 1 in. larger than unit all round, level, separate from house |
| Cold climate (HP) | raise 3-12 in. above pad |
| Within 1 mile of salt water | add BAYSEAC001 if no factory salt shield |
| Operating range | cooling 55-120 F, heating 0-66 F |
How to use the Trane Heat Pump Outdoor unit placement table
Find your exact model in the first column and read across the row. Values in the Trane Heat Pump Outdoor unit placement table are a summary for quick reference; the rating plate on the unit and the manufacturer's manual for your model always decide. If your model is not listed, or a value looks different from what you see on the unit, check the manual before changing anything.
Notes
- Avoid bedroom walls and under roof drip lines.
Applies to: 5TTR7 and 5TWR7, 024A-060A
Trane models this applies to
5TWR7024A5TWR7036A5TWR7048A5TWR7060A
Source: Trane ODR-SVN002E-EN (5TTR7/5TWR7) - Location Considerations / Table 1. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.