Common causes of compressor will not run - winding and electrical checks - carrier split systems

  • Internal overload open (hot compressor)
  • Open, shorted or grounded winding
  • Bad run/start capacitor or PTC
  • Low voltage
  • Locked rotor

How to fix compressor will not run - winding and electrical checks - carrier split systems: step by step

  1. Let a hot compressor cool so the internal line break can reset.
  2. Power off, discharge capacitors, remove C, S, R leads.
  3. Find terminals: largest reading is S-R, the remaining terminal is C; C-S is the higher of the other two.
  4. An open reading on any pair means an open winding - replace.
  5. Check to ground with a megger or high ohms scale; low reading means grounded - replace.
  6. Check capacitors; replace any bulged or leaking one. PTC start thermistor 12.5-ohm type should read 12.5-22.5 ohms.
  7. If the compressor draws locked-rotor amps with all external causes cleared, replace it and check the system for the root cause.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Carrier Air Conditioner codes

Models

Carrier 2-stage 24ANB/25HNB

24ANB12424ANB13624ANB14824ANB16024ANB72424ANB73624ANB74824ANB760

Carrier Infinity 19VS 24VNA9

24VNA924VNA91324VNA92424VNA92524VNA93624VNA93724VNA94824VNA94924VNA960

Source: Carrier Residential AC & HP Application Guideline and Service Manual 24-25-9SM (text export), Compressor Troubleshooting. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977