Bosch Greentherm T9900 i 199 Error Codes

Updated · by Aurora Star Tech Inc.

Bosch Greentherm T9900 i 199 error codes and diagnostic codes (also listed as T9900 i 199, i 199). The Greentherm T9900 i 199 is a Bosch tankless water heater in the Bosch Greentherm T9900 SE series.

Homeowner with a tankless water heater problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Bosch Greentherm T9900 i 199 error codes list

CodeMeaningSeverity
A0Water temperature sensors disconnected or damagedMedium
A1Cabinet air temperature above 158 F (70 C)Medium
A2External water temperature sensor / aquastat faultLow
A3Flue gas temperature sensor faultMedium
A4Air temperature sensor faultMedium
A5Condensing unit flue temperature sensor faultMedium
A6Inlet cold water temperature sensor faultMedium
A7Heat exchanger hot water temperature sensor faultMedium
A8Outlet hot water temperature sensor faultMedium
A9Output power too lowMedium
AAFlue gas temperature too high, power limitedMedium
ACAC consumptionLow
ADPower derate warningLow
AUAU technical settings (service mode)Low
BBFan calibration after missed ignitionsMedium
BCRepeated fan calibration with similar valuesMedium
Burner symbolBurner status symbol - burner onLow
C1Flue blockage at start-upHigh
C2Flue blockage at start-upHigh
C3Flow sensor sees no recirculationLow
C5Bypass water valve faultMedium
C7Fan faultHigh
C8Main water valve faultMedium
C9Barometric pressure sensor damagedMedium
CAWater flow above 9.2 gpmLow
CEFlue blockage during operation (siphon pressure)High
CFFlue blockage during operation (insufficient air)High
DHDH data historyLow
Display blankDisplay blank - appliance offLow
E0Control unit internal errorMedium
E1Hot water above 194 F (90 C)High
E3Flue gas temperature too high, burner cut offHigh
E4Cabinet air too hot, burner cut offHigh
E5Condensing unit flue too hot, burner cut offHigh
E7Control unit internal errorMedium
E8Ionization test errorMedium
E9Thermal fuse openHigh
EAIgnition failureHigh
EBControl unit internal errorMedium
ECFlame lost during operationHigh
EEGas valve modulation coil disconnectedHigh
EFWrong gas type configuredHigh
Error resetHold ON/OFF key to clear an error codeLow
F2Control unit internal errorMedium
F3Control unit internal error / configurationMedium
F7Control unit internal errorMedium
F8Control unit internal errorMedium
F9Gas valve driver faultHigh
FAGas leak in the gas pathCritical
FCTouch key held over 20 secondsLow
FHFH failure historyLow
HSHS aboutLow
ODOD operation dataLow
Open TapsOpen Taps message during auto adjustLow
P4P4 Information menuLow
P9P9 purge menuLow
PAPA water actuator (valve calibration)Low
PEPE appliance type (read-only data)Low
SASA settings menuLow
Setpoint displaySet temperature shown on touch displayLow
Solar modeSolar mode indicatorLow
UCUC auto adjust (gas and air)Low

Troubleshooting the Greentherm T9900 i 199

All Bosch Tankless Water Heater error codes →

Homeowner help: Tankless Water Heater No Hot Water: What to Check

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.