Trane Error Code Ld: Lockout: high discharge temperature (Heat Pump)

Updated · by Aurora Star Tech Inc.

Trane error code Ld on a heat pump means: Lockout: high discharge temperature. It is also called Trane diagnostic code Ld.

High severityHeat PumpTrane 5TWR7

Homeowner? What Trane code Ld means for you

Call a technician Your heat pump is reporting: Lockout: high discharge temperature. The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Safe things you can check yourself

  • Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
  • Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
  • Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
  • In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
  • Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.

Call (647) 657-2977Book a service call

Licensed technicians serving Vaughan, Toronto and the GTA.

What does Trane error code Ld mean?

Repeated high discharge temperature caused a lockout. Manual lists only the meaning (A1000BA board); steps are general checks drawn from other sections of the guide.

Applies to: Trane 5TWR7 multi-speed heat pump (5TWR7024A-060A)

Common causes of Trane code Ld

  • Low charge
  • Restriction
  • Sensor error
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Trane models that use code Ld

5TWR7024A5TWR7036A5TWR7048A5TWR7060A

Other Trane Heat Pump codes

CodeMeaning
HLHard lock: low pressure (LPCO)
L5Lockout: drive AC input over-current
L6Lockout: high drive IPM temperature
L7Lockout: high drive PFC temperature
L8Lockout: high coil temperature
LCLockout: compressor over-current
LFLockout: outdoor fan over-current
LHLockout: high pressure (HPCO / DTC)
LLLockout: low pressure (LPCO)

All Trane Heat Pump error codes →

Trane code Ld: homeowner questions

What does Trane code Ld mean?

Lockout: high discharge temperature. Repeated high discharge temperature caused a lockout. Manual lists only the meaning (A1000BA board); steps are general checks drawn from other sections of the guide.

Is it safe to keep using my heat pump with code Ld?

It depends on the cause. The heat pump has locked out or cannot run properly. One reset is fine; if the code comes back, it needs a licensed technician to find the cause.

Can I reset Trane code Ld myself?

You can try one reset (power off for 30 seconds, then on). If Trane code Ld comes back, the cause is still there and a licensed technician should check it.

Who can fix Trane code Ld near me?

Aurora Star Tech Inc. repairs Trane heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.

Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air

Troubleshooting guides

Source: Trane ODR-SVN002E-EN (5TTR7/5TWR7 installer's guide) - section Integrated Variable Speed Control Board LED Indicators, Table 18 (A1000BA models). Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.