Fujitsu Error Code 71: Discharge temperature sensor error (Heat Pump)
Fujitsu error code 71 on a heat pump means: Discharge temperature sensor error. It is also called Fujitsu diagnostic code 71.
Homeowner? What Fujitsu code 71 means for you
Check, then call Your heat pump is reporting: Discharge temperature sensor error. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.
Safe things you can check yourself
- Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
- Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
- Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
- In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
- Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.
Call (647) 657-2977Book a service call
Licensed technicians serving Vaughan, Toronto and the GTA.
What does Fujitsu error code 71 mean?
Outdoor discharge pipe thermistor reads open or shorted at power-up or while the compressor runs. Indoor lamps: OPERATION (green) flashes 7x, TIMER (orange) flashes 1x, ECONOMY (green) flashes fast nonstop; wired remote shows 71.
Applies to: Fujitsu ductless heat pumps: Fujitsu ductless split/multi/VRF (general code list), Fujitsu wall-mounted 7-15 (NA ASU/AOU type), Fujitsu slim duct ARU 7-18 (LL type)
Common causes of Fujitsu code 71
- Plug loose
- Thermistor failure
- Outdoor main PCB failure
Other Fujitsu Heat Pump codes
All Fujitsu Heat Pump error codes →
Fujitsu code 71: homeowner questions
What does Fujitsu code 71 mean?
Discharge temperature sensor error. Outdoor discharge pipe thermistor reads open or shorted at power-up or while the compressor runs. Indoor lamps: OPERATION (green) flashes 7x, TIMER (orange) flashes 1x, ECONOMY (green) flashes fast nonstop; wired remote shows 71.
Is it safe to keep using my heat pump with code 71?
It depends on the cause. This is often caused by something simple. Try the safe checks below; if the code returns, book a service call before it turns into a no-heat or no-hot-water emergency.
Can I reset Fujitsu code 71 myself?
You can try one reset (power off for 30 seconds, then on). If Fujitsu code 71 comes back, the cause is still there and a licensed technician should check it.
Who can fix Fujitsu code 71 near me?
Aurora Star Tech Inc. repairs Fujitsu heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air
Troubleshooting guides
- 2 flashes: HPS open ≥6 s; 3: discharge >263°F; 4: discharge <90°F after 1 h; 5: defrost failure; 6: discharge sensor short; 7: outdoor sensor open/short; 9: bonnet sensor fail All brands · Heat Pump
- Auxiliary heat indicator light is on All brands · Heat Pump
- Cleaning the outdoor unit finish All brands · Heat Pump
- Excess ice on outdoor coil All brands · Heat Pump
- Extremely high head pressure in heating (dual fuel) All brands · Heat Pump
- Insufficient heat in cold weather All brands · Heat Pump
- Liquid slugging / compressor damage in heating All brands · Heat Pump
- No mode change / wrong mode All brands · Heat Pump
Source: Fujitsu All Fujitsu split - multi - VRF (generic code list) codes.pdf - section error code table (indoor LED flashes); Fujitsu Wall-mounted 7-9-12-15 (North American trilingual, UTY-RNNUM remotes; e.g. ASU9-12-15 RLF1-RLS familie.pdf - section 14 Error codes; Fujitsu Wall-mounted KMCG (ASEH-AOEH 07-14) - Fujitsu UK; same error-code scheme as NA ASU-AOU units service S.pdf - section 3 Troubleshooting, 2 Troubleshooting with error code; Fujitsu Slim duct AR07-09-12-14-18 (ARU-ARYG LL-type equivalent) installation P-N 9381858064.pdf - section 14 Error codes. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.