Bosch Error Code AtL: Ambient temperature limited (Heat Pump)
Bosch error code AtL on a heat pump means: Ambient temperature limited. It is also called Bosch diagnostic code AtL.
Homeowner? What Bosch code AtL means for you
Usually minor Your heat pump is reporting: Ambient temperature limited. This code is usually informational or minor. The safe checks below often clear it; call us if it keeps showing up.
Safe things you can check yourself
- Check the thermostat: right mode (Heat or Cool), set a few degrees past room temperature, and fresh batteries if it uses them.
- Check both breakers and the outdoor disconnect box beside the outdoor unit; all should be ON.
- Look at the air filter. If it is grey and clogged, replace it; a blocked filter causes many shutdowns.
- In winter, keep snow and ice off and away from the outdoor unit. A short defrost cycle with steam is normal.
- Try one reset: turn the power off for 30 seconds, then back on. If the code comes back, stop resetting and call a technician.
Call (647) 657-2977Book a service call
Licensed technicians serving Vaughan, Toronto and the GTA.
What does Bosch error code AtL mean?
Operation is restricted because the outdoor temperature is outside the operating range.
Applies to: Bosch IDS Light BOVA15-24/36/60 and IDS Premium Connected BOVA36-20/60-20 R-454B heat pump outdoor units
Common causes of Bosch code AtL
- Ambient outside 15-125 F in cooling or -4 to 86 F in heating
- Thermostat O/B setting wrong
- T4 sensor wiring or reading wrong
Bosch models that use code AtL
BOVA15-24BOVA15-36BOVA15-60BOVA36-20BOVA60-20
Other Bosch Heat Pump codes
All Bosch Heat Pump error codes →
Bosch code AtL: homeowner questions
What does Bosch code AtL mean?
Ambient temperature limited. Operation is restricted because the outdoor temperature is outside the operating range.
Is it safe to keep using my heat pump with code AtL?
Usually yes. Code AtL is normally minor, but if it keeps coming back have it checked.
Can I reset Bosch code AtL myself?
You can try one reset (power off for 30 seconds, then on). If Bosch code AtL comes back, the cause is still there and a licensed technician should check it.
Who can fix Bosch code AtL near me?
Aurora Star Tech Inc. repairs Bosch heat pumps in Vaughan, Toronto and across the GTA. Call (647) 657-2977 or book a service call online.
Homeowner help: AC Running But Not Cooling: What to Check · Heat Pump Not Heating or Blowing Cold Air
Source: Bosch IDS Light installation BTC 762003308 D (02.2025), Fault Code Table 23 and 17.12 Error Code Troubleshooting, p.42-59; Bosch IDS Premium Connected installation BTC 762003301 D (02.2025), Fault Code Table 22 and 18.12 Error Code Troubleshooting. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.