Noritz Operation panel menu settings and defaults
Noritz Operation panel menu settings and defaults: reference table for the tankless water heater (Noritz EZ, Noritz NRCR series): a quick-reference table with notes.
Noritz Operation panel menu settings and defaults table
| Setting | Options | Default |
|---|---|---|
| Max Set Temperature (power off) | 100-140 F in 5 F steps; 37-48 C, 50-60 C | 120 F / 50 C |
| Recirc ON/OFF | ON / OFF | OFF |
| Recirc Mode | Always OFF, Always ON, Manual Timer, Auto Learning (NRCR) | Always OFF |
| Vacation Mode | Active / Inactive | Inactive |
| Flow Meter Alarm | 10-60 gal (5 gal steps), 70-100 gal (10 gal steps), OFF | Alarm OFF |
| Drain Water (power off) | Start / Cancel | Cancel |
| Scale Flushing (power off) | Start / Cancel | Cancel |
| Audible Alarm | ON / OFF | ON |
| Screen Lock | Active / Inactive (4-digit password) | Inactive |
| Units (first 10 min after power-up, power off) | [F/gal/ft] or [C/L/m] | [F/gal/ft] |
| Power Saving Dis. / Backlight | ON-OFF / Power Save ON-OFF | ON / Power Save ON |
| Brightness / Contrast / Touch Sound | Bright-Normal-Dim-Dark / -15 to +15 / ON-OFF | Normal / Standard / ON |
How to use the Noritz Operation panel menu settings and defaults table
Find your exact model in the first column and read across the row. Values in the Noritz Operation panel menu settings and defaults table are a summary for quick reference; the rating plate on the unit and the manufacturer's manual for your model always decide. If your model is not listed, or a value looks different from what you see on the unit, check the manual before changing anything.
Notes
- Setting 125 F (55 C) or higher needs Max Set Temperature raised first; the panel warns about scald risk.
- Default Settings resets everything in Settings except Screen Lock (hold OK about 5 s).
- Forgot screen lock password: hold OK 5 s while 'Input Password' is shown.
- Menu also has Maintenance Monitor, Sys. Maint. Monitor (multi-unit), Error History (last 8) and Heater Info.
Applies to: Noritz EZ111/EZ98/EZ71 and NRCR111/NRCR92
Noritz models this applies to
Noritz EZ
Noritz NRCR
Noritz Tankless Water Heater error codes →
Source: Noritz EZ/NRCR Owner's Guide (Rev. 10-25), Configuring settings using the operation panel, p.15-20. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.