Navien Installation clearances (indoor / outdoor)

Updated · by Aurora Star Tech Inc.

Navien Installation clearances (indoor / outdoor): reference table for the tankless water heater (Navien NPE-2 series): a quick-reference table with notes.

Tankless Water HeaterClearancesNavien NPE-2

Navien Installation clearances (indoor / outdoor) table

SideIndoorOutdoor
Top9 in. (229 mm)36 in. (900 mm)
Back0.5 in. (13 mm)0.5 in. (13 mm)
Front4 in. (100 mm)24 in. (600 mm)
Sides3 in. (76 mm)3 in. (76 mm)
Bottom12 in. (300 mm)12 in. (300 mm)

How to use the Navien Installation clearances (indoor / outdoor) table

Find your exact model in the first column and read across the row. Values in the Navien Installation clearances (indoor / outdoor) table are a summary for quick reference; the rating plate on the unit and the manufacturer's manual for your model always decide. If your model is not listed, or a value looks different from what you see on the unit, check the manual before changing anything.

Notes

  • Vent clearance to combustibles is 0 in.
  • Outdoor: use the Navien Outdoor Vent Kit; keep 3 ft from an eave to the top of the vent terminals; mild climates only.
  • Keep room temp between 32 F (0 C) and 125 F (52 C).
  • Common vent installs: 36 in. top and 24 in. front recommended for service.

Applies to: Navien NPE-A2 (built-in recirculation) and NPE-S2 condensing tankless water heaters: NPE-150S2, NPE-180A2/S2, NPE-210A2/S2, NPE-240A2/S2

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Navien models this applies to

NPE-150S2NPE-180A2NPE-180S2NPE-210A2NPE-210S2NPE-240A2NPE-240S2

Navien Tankless Water Heater error codes →

Source: Navien NPE-A2/S2 Installation Manual, 3.1 Adequate Installation Clearances, p.17; Outdoor Installation, p.59. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.