Napoleon Framing and combustible clearances

Updated · by Aurora Star Tech Inc.

Napoleon Framing and combustible clearances: reference table for the gas fireplace (Napoleon GD70 STARfire series): a quick-reference table with notes.

Gas FireplaceClearancesNapoleon GD70 STARfire

Napoleon Framing and combustible clearances table

ItemClearance / size
Framing to stand-offs (top, rear, sides)0 in.
Finishing material to sides of unit3 in.
Finishing material to top of unit7 1/4 in.
Objects in front of fireplace48 in. from front face
Vent pipe to combustibles1 in.
Wall opening for horizontal vent11 1/2 in. min. square or round
Ceiling/roof opening for vertical vent9 1/2 in.
Non-combustible facing over front (GD425 kit)3/4 in. max. thickness
Gas flex connector (Massachusetts)36 in. max. length

How to use the Napoleon Framing and combustible clearances table

Find your exact model in the first column and read across the row. Values in the Napoleon Framing and combustible clearances table are a summary for quick reference; the rating plate on the unit and the manufacturer's manual for your model always decide. If your model is not listed, or a value looks different from what you see on the unit, check the manual before changing anything.

Notes

  • Hearth extension not required; raise unit to finished floor height so the lower door and trim clear.
  • Non-combustible finish can be skipped if the optional 6 in. bevelled trim is used.
  • Vent must be supported about every 3 ft with 1 in. clearance kept to combustibles.

Applies to: Napoleon GD70NT-S (natural gas) and GD70PT-S (propane) STARfire direct vent fireplaces

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Napoleon models this applies to

GD70NT-SGD70PT-S

Napoleon Gas Fireplace error codes →

Source: Napoleon GD70NT-S / GD70PT-S installation & operating instructions W415-0434/C, Installation pp.4, 11, 14; Framing p.15. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.