Midea Heat Pump Outdoor unit minimum clearances

Updated · by Aurora Star Tech Inc.

Midea Heat Pump Outdoor unit minimum clearances: reference table for the heat pump (Midea DLCURA ducted single-zone inverter heat pump (outdoor) series): a quick-reference table with notes.

Heat PumpClearancesMidea DLCURA ducted single-zone inverter heat pump (outdoor)

Midea Heat Pump Outdoor unit minimum clearances table

SideMinimum
A - top24 in. (610 mm)
B - right side (service side)24 in. (610 mm)
C - front (air outlet)24 in. (610 mm)
D - left side4 in. (101 mm)
E - rear (air inlet)4 in. (101 mm)
Above max snow depth2 in. (50 mm)

How to use the Midea Heat Pump Outdoor unit minimum clearances table

Find your exact model in the first column and read across the row. Values in the Midea Heat Pump Outdoor unit minimum clearances table are a summary for quick reference; the rating plate on the unit and the manufacturer's manual for your model always decide. If your model is not listed, or a value looks different from what you see on the unit, check the manual before changing anything.

Notes

  • Side letters taken from Fig. 8 drawing.
  • Units facing each other: 59 in. (150 cm) or more; do not blow into another unit's inlet.
  • Do not bury more than 36 in. of line set; buried lines need a 6 in. rise at the valves.

Applies to: DLCURAH18AAK, DLCURAH18ABK, DLCURAH24AAK, DLCURAH24ABK, DLCURAH30AAK, DLCURAH30ABK, DLCURAH36AAK, DLCURAH36ABK, DLCURAH48AAK, DLCURAH48ABK, DLCURAH60AAK, DLCURAH60ABK (all 208/230V-1ph)

Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

Midea models this applies to

DLCURAH18AAKDLCURAH18ABKDLCURAH24AAKDLCURAH24ABKDLCURAH30AAKDLCURAH30ABKDLCURAH36AAKDLCURAH36ABKDLCURAH48AAKDLCURAH48ABKDLCURAH60AAKDLCURAH60ABK

Midea Heat Pump error codes →

Source: Midea DLCURA Installation Instructions (Catalog No. DLCURA-03SI, 12/22), Table 5 Clearance Dimensions and Fig. 8-9, PDF p.10 (printed p.8); burial caution PDF p.4. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.