Navien Tankless Water Heater: Water not hot enough or too hot – Navien NPE-2
Water not hot enough or too hot - Navien NPE-2 on a Navien tankless water heater: Hot water temperature is lower or higher than expected.
Applies to: Navien NPE-A2 (built-in recirculation) and NPE-S2 condensing tankless water heaters: NPE-150S2, NPE-180A2/S2, NPE-210A2/S2, NPE-240A2/S2
Common causes of water not hot enough or too hot - navien npe-2
- Set temperature wrong
- Cross plumbing between hot and cold lines
- Temperature lock on
- Commercial Mode off
How to fix water not hot enough or too hot - navien npe-2: step by step
- Check the set temperature (factory 120 F / 49 C). Range 97-140 F; while a tap is open it can only be changed between 97-110 F.
- For not hot enough, check for cross plumbing (e.g. faulty mixing valve) between the hot and cold lines.
- If the temperature cannot be changed, front-panel DIP switch 2 (temperature lock) may be ON.
- Above 140 F (up to 185 F) requires Commercial Mode: Installer Menu > Parameter 12 (temperature lock must be OFF).
- WARNING: water at or above 125 F can scald instantly - recommend a mixing valve before raising the setting.
If the unit shows an error code, look it up: Navien Tankless Water Heater codes
Models
Navien NaviCirc
Navien NHW700
NHW700-120SENHW700-160AENHW700-160AINHW700-160SENHW700-160SUNHW700-180AENHW700-180AINHW700-180SENHW700-180SUNHW700-199AENHW700-199AINHW700-199SENHW700-199SU
Navien NPE-2
NPE-150S2NPE-180A2NPE-180S2NPE-210A2NPE-210S2NPE-240A2NPE-240S2
Navien NPN
NPN-120ENPN-160ENPN-160UNPN-180ENPN-180UNPN-199ENPN-199U
Source: Navien NPE-A2/S2 User's Information Manual (20049624A), 5.1, p.16; Navien NPE-A2/S2 Installation Manual, 7.3, p.91-92. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.