Navien Tankless Water Heater: Water not hot enough or too hot – Navien NPE-2

Updated · by Aurora Star Tech Inc.

Water not hot enough or too hot - Navien NPE-2 on a Navien tankless water heater: Hot water temperature is lower or higher than expected.

Homeowner with a tankless water heater problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Navien NPE-A2 (built-in recirculation) and NPE-S2 condensing tankless water heaters: NPE-150S2, NPE-180A2/S2, NPE-210A2/S2, NPE-240A2/S2

Common causes of water not hot enough or too hot - navien npe-2

  • Set temperature wrong
  • Cross plumbing between hot and cold lines
  • Temperature lock on
  • Commercial Mode off

How to fix water not hot enough or too hot - navien npe-2: step by step

  1. Check the set temperature (factory 120 F / 49 C). Range 97-140 F; while a tap is open it can only be changed between 97-110 F.
  2. For not hot enough, check for cross plumbing (e.g. faulty mixing valve) between the hot and cold lines.
  3. If the temperature cannot be changed, front-panel DIP switch 2 (temperature lock) may be ON.
  4. Above 140 F (up to 185 F) requires Commercial Mode: Installer Menu > Parameter 12 (temperature lock must be OFF).
  5. WARNING: water at or above 125 F can scald instantly - recommend a mixing valve before raising the setting.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Navien Tankless Water Heater codes

Models

Navien NaviCirc

NaviCirc

Navien NHW700

NHW700-120SENHW700-160AENHW700-160AINHW700-160SENHW700-160SUNHW700-180AENHW700-180AINHW700-180SENHW700-180SUNHW700-199AENHW700-199AINHW700-199SENHW700-199SU

Navien NPE-2

NPE-150S2NPE-180A2NPE-180S2NPE-210A2NPE-210S2NPE-240A2NPE-240S2

Navien NPN

NPN-120ENPN-160ENPN-160UNPN-180ENPN-180UNPN-199ENPN-199U

Source: Navien NPE-A2/S2 User's Information Manual (20049624A), 5.1, p.16; Navien NPE-A2/S2 Installation Manual, 7.3, p.91-92. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977