Navien Tankless Water Heater: No water from hot tap – Navien NPE-2
No water from hot tap - Navien NPE-2 on a Navien tankless water heater: Check first, before touching anything, whether the unit has power and the isolation valves are open. On a Navien NPE-A2 or NPE-S2, nothing coming out of the hot tap may be as simple as a closed shut-off valve or a plugged cold inlet filter. If it is winter, confirm the unit is not frozen, because a frozen heat exchanger blocks the flow completely. Do not use open flame to thaw it, and look for leaks once it thaws. If a code is on the display, follow the code before anything else.
Applies to: Navien NPE-A2 (built-in recirculation) and NPE-S2 condensing tankless water heaters: NPE-150S2, NPE-180A2/S2, NPE-210A2/S2, NPE-240A2/S2
Common causes of no water from hot tap - navien npe-2
- Shut-off valves closed
- Clogged cold water inlet filter
- Unit frozen
- Error code active
How to fix no water from hot tap - navien npe-2: step by step
- Make sure the shut-off valves on the hot and cold lines at the heater are open
- Clean the cold water inlet filter, close the isolation valves first and have a bucket ready
- If an error code shows, look it up and follow it
- If frozen: turn the unit off, close the gas valve, open the nearest hot tap and warm both heat exchangers with a hair dryer or portable heater, never an open flame, and check for leaks once water flows
- Prevent freezing: keep power connected (freeze protection needs electricity), keep the gas on (A2 models) and drain the unit if power or gas will be off for a long time
- Call a licensed tech if water leaks after thawing
If the unit shows an error code, look it up: Navien Tankless Water Heater codes
Models
Navien NaviCirc
Navien NHW700
NHW700-120SENHW700-160AENHW700-160AINHW700-160SENHW700-160SUNHW700-180AENHW700-180AINHW700-180SENHW700-180SUNHW700-199AENHW700-199AINHW700-199SENHW700-199SU
Navien NPE-2
NPE-150S2NPE-180A2NPE-180S2NPE-210A2NPE-210S2NPE-240A2NPE-240S2
Navien NPN
NPN-120ENPN-160ENPN-160UNPN-180ENPN-180UNPN-199ENPN-199U
Source: Navien NPE-A2/S2 User's Information Manual (20049624A), 5.1 Solving Basic Problems, p.16; 4.6, p.15. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.