Navien Tankless Water Heater: Hot water turns cold – Navien NPE-2
Hot water turns cold - Navien NPE-2 on a Navien tankless water heater: Hot water goes cold and stays cold. Navien NPE-A2 or NPE-S2. Flow, filter, code, gas. Check in that order. Burner needs at least 0.5 GPM to fire. Low flow is the easy miss. Low gas at high demand is the other one.
Applies to: Navien NPE-A2 (built-in recirculation) and NPE-S2 condensing tankless water heaters: NPE-150S2, NPE-180A2/S2, NPE-210A2/S2, NPE-240A2/S2
Common causes of hot water turns cold - navien npe-2
- Clogged inlet filter
- Flow below the 0.5 GPM minimum
- Error code
- Missing check valve on an external recirculation return
- Gas pressure dropping at high demand
How to fix hot water turns cold - navien npe-2: step by step
- Clean the cold water inlet filter, isolate and drain first
- Open the tap fully, at least 0.5 GPM must flow to fire the unit
- Check the display for an error code and look it up
- With an external recirculation system, make sure a check valve is on the recirculation return line, or cold water backfeeds into the hot side
- Check gas pressure at max fire (3.5-10.5 in. WC NG, 8.0-13 in. WC LP) if it happens at high demand, gas work is for a licensed tech
- Try one fixture only to see whether it is a capacity issue
- Check for a crossover at mixing valves or single-handle faucets
If the unit shows an error code, look it up: Navien Tankless Water Heater codes
Models
Navien NaviCirc
Navien NHW700
NHW700-120SENHW700-160AENHW700-160AINHW700-160SENHW700-160SUNHW700-180AENHW700-180AINHW700-180SENHW700-180SUNHW700-199AENHW700-199AINHW700-199SENHW700-199SU
Navien NPE-2
NPE-150S2NPE-180A2NPE-180S2NPE-210A2NPE-210S2NPE-240A2NPE-240S2
Navien NPN
NPN-120ENPN-160ENPN-160UNPN-180ENPN-180UNPN-199ENPN-199U
Source: Navien NPE-A2/S2 User's Information Manual (20049624A), 5.1 Solving Basic Problems, p.16. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.