Navien Tankless Water Heater: Hot water slow to reach fixtures – Navien NPE-2
Hot water slow to reach fixtures - Navien NPE-2 on a Navien tankless water heater: If you turn on a tap and wait forever for hot water on a Navien NPE-A2 or NPE-S2, the heater is probably fine. The wait comes from the pipe run, because the water sitting in the line has to be pushed out before hot water gets there. Recirculation fixes that by keeping hot water moving, but the unit has to be set up and the plumbing has to support it. Here is what to look at.
Applies to: Navien NPE-A2 (built-in recirculation) and NPE-S2 condensing tankless water heaters: NPE-150S2, NPE-180A2/S2, NPE-210A2/S2, NPE-240A2/S2
Common causes of hot water slow to reach fixtures - navien npe-2
- No recirculation return line
- Recirculation mode not set
- 2-way valve on an A2 set to the wrong position
- External recirculation run too long for the built-in pump
How to fix hot water slow to reach fixtures - navien npe-2: step by step
- A2 models: use Internal Recirculation (2-way valve set to INT) for faster delivery, or External Recirculation (valve set to EXT) with a return line from the farthest fixture
- S2 models need an external pump and return line (or NaviCirc valve)
- Set Menu > 1. Recirculation Settings to Always On, Intelligent, Weekly or HotButton, pick the one that fits the household
- Built-in pump limits on external recirculation: 100 ft equivalent of 1/2 in. copper or 500 ft of 3/4 in. copper, longer runs need an external pump
- Insulate the hot lines to hold the heat longer
- Explain to the homeowner what each mode costs in gas and electricity
If the unit shows an error code, look it up: Navien Tankless Water Heater codes
Models
Navien NaviCirc
Navien NHW700
NHW700-120SENHW700-160AENHW700-160AINHW700-160SENHW700-160SUNHW700-180AENHW700-180AINHW700-180SENHW700-180SUNHW700-199AENHW700-199AINHW700-199SENHW700-199SU
Navien NPE-2
NPE-150S2NPE-180A2NPE-180S2NPE-210A2NPE-210S2NPE-240A2NPE-240S2
Navien NPN
NPN-120ENPN-160ENPN-160UNPN-180ENPN-180UNPN-199ENPN-199U
Source: Navien NPE-A2/S2 User's Information Manual (20049624A), 5.1, p.16; Navien NPE-A2/S2 Installation Manual, 3.4.2, p.27-29. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.