Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

ICP Heat Pump: Comfort Alert module basics

Updated · by Aurora Star Tech Inc.

Comfort Alert module basics on a ICP heat pump: The Comfort Alert module on the ICP N4H3 R-410A split heat pump (manual 428 01 5103 02) has three lights, and reading them correctly saves a lot of guessing. These codes apply only to units that were factory fitted with the Comfort Alert module. Confirm the module is present before relying on any of this, and treat the electrical checks as work for a qualified technician.

Homeowner with a heat pump problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: ICP N4H3 R-410A split heat pump (manual 428 01 5103 02); Comfort Alert codes apply only to units factory-fitted with the Comfort Alert module

Common causes of comfort alert module basics

  • Green POWER means the module is powered
  • Red TRIP means there is a Y1 call but the compressor is off
  • Yellow ALERT flashes a code: a number of flashes, a pause, then it repeats

How to fix comfort alert module basics: step by step

  1. The module is powered from R and C (24 VAC) and watches the compressor leads and Y, so confirm 24 VAC at those terminals first.
  2. Reset an ALERT code by removing 24 VAC from the module.
  3. The last ALERT code shows for 1 minute after the module powers on, so count the flashes during that window.
  4. TRIP and ALERT flashing together means control voltage is too low; check the transformer and low voltage wiring.
  5. Match the flash count to the module's code table before replacing any component
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: ICP Heat Pump codes

Models

N4H3

Source: ICP N4H3 Installation Instructions 428 01 5103 02, Troubleshooting / Figure 17-18, p.19-20. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.