Icon
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Napoleon Gas Fireplace: Venturi / air shutter adjustment

Updated · by Aurora Star Tech Inc.

Venturi / air shutter adjustment on a Napoleon gas fireplace: Set flame colour; may need adjusting for fuel, vent configuration and altitude.

Homeowner with a gas fireplace problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Napoleon gas fireplaces - direct vent, natural vent and vent-free (general service manual); GD70 note from GD70 manual

Common causes of venturi / air shutter adjustment

  • Air shutter not set for vent length/fuel/altitude

How to fix venturi / air shutter adjustment: step by step

  1. Loosen the securing screw and rotate the venturi to open or close.
  2. Closing gives a yellower flame but can cause carboning; opening gives a bluer flame but can lift flames off the ports.
  3. Wait 15-30 minutes for the final flame colour before judging.
  4. GD70: factory set for the longest horizontal run (20 ft); shorter runs need adjustment (propane can go as low as 1/4" open). Access by removing the two cover screws on the air housing without damaging the gasket. WARNING: qualified gas installer only.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Napoleon Gas Fireplace codes

Models

GD70NT-SGD70PT-S

Source: Napoleon (Wolf Steel) Service Manual W415-0118, Part 5 Testing & Adjustments, Adjustments: Venturi p.44; GD70 W415-0434 Maintenance section. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service