Napoleon Gas Fireplace: Test: spill switch and wall switch/thermostat wiring

Updated · by Aurora Star Tech Inc.

Test: spill switch and wall switch/thermostat wiring on a Napoleon gas fireplace: Isolate a bad switch from bad wiring, and check spill switch continuity.

Homeowner with a gas fireplace problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Napoleon gas fireplaces (spill switch applies to natural-vent units)

Common causes of test: spill switch and wall switch/thermostat wiring

  • Failed spill switch
  • Failed wall switch/thermostat
  • Damaged wiring

How to fix test: spill switch and wall switch/thermostat wiring: step by step

  1. Spill switch: disconnect all wires, meter on ohms across the two spade terminals; the manual says replace the switch if it reads 1 ohm or higher.
  2. Wall switch/thermostat: with switch leads on valve terminals 1 & 3 (top and bottom), disconnect the leads at the switch end and join them together.
  3. Turn the valve on - if the burner lights, the wiring is good and the switch is faulty.
  4. WARNING: a spill switch / vent safety switch may be bypassed only temporarily for testing - it is illegal to leave it bypassed. Restore before leaving.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Napoleon Gas Fireplace codes

Models

GD70NT-SGD70PT-S

Source: Napoleon (Wolf Steel) Service Manual W415-0118, Part 5 Testing & Adjustments, Testing: Switches p.32; Adjustments: Spill Switch p.42-43. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.