Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Napoleon Gas Fireplace: Test: door gasket seal (paper test)

Updated · by Aurora Star Tech Inc.

Test: door gasket seal (paper test) on a Napoleon gas fireplace: This is the old paper test for a door gasket on Napoleon gas fireplaces, direct vent, natural vent or vent-free. What I usually find on a call-back is a gasket that has flattened out or a latch that has loosened up, and the paper shows it in about a minute. A leaky door on a direct vent unit upsets combustion air balance and can let products of combustion into the room, so it is worth doing right.

Homeowner with a gas fireplace problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Napoleon gas fireplaces - direct vent, natural vent and vent-free (general service manual)

Common causes of test: door gasket seal (paper test)

  • Worn or damaged door gasket
  • Latch worn or out of adjustment so the door does not pull tight

How to fix test: door gasket seal (paper test): step by step

  1. Cut a strip of paper about 1" x 6" and place it between the door and the fireplace body, then close and latch the door.
  2. Pull the paper out. If it tears rather than slipping out, the seal is good there; if it slides out, inspect the door, gasket and latch.
  3. Repeat at several positions around the frame, not just one spot.
  4. Look for an even colour line on the firebox opening where the gasket presses; it should not extend past the gasket perimeter.
  5. Replace a hardened or crushed gasket and adjust or replace the latch before putting the unit back in service
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Napoleon Gas Fireplace codes

Models

GD70NT-SGD70PT-S

Source: Napoleon (Wolf Steel) Service Manual W415-0118, Part 5 Testing & Adjustments, Testing: Gasket, p.32. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977