Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Napoleon Gas Fireplace: Pilot will not stay lit – natural vent

Updated · by Aurora Star Tech Inc.

Pilot will not stay lit - natural vent on a Napoleon gas fireplace: On a Napoleon natural-vent (B-vent) fireplace, the usual thing I find when the pilot won't hold is a weak thermocouple or thermopile signal, or a spill switch that has opened up. People forget the spill switch is wired into the same circuit, so a loose spade connector there kills the pilot just like a bad thermocouple does. Before replacing parts, check connections and the millivolt readings. A blocked pilot tube or an undersized gas line is the next likely candidate.

Homeowner with a gas fireplace problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Napoleon natural-vent (B-vent) gas fireplaces with spill switch (general service manual flowchart)

Common causes of pilot will not stay lit - natural vent

  • Loose thermocouple or thermopile connection
  • Low millivolt output
  • Blocked pilot tube or orifice
  • Undersized supply line
  • Spill switch disconnected or open, which is a vent safety and must be found, not bypassed
  • Weak magnet coil in the valve

How to fix pilot will not stay lit - natural vent: step by step

  1. Check and tighten thermocouple and thermopile connections at the valve
  2. Test millivolt output (thermocouple 20-30 mV open / 10-15 mV closed; thermopile 500 mV open / min 150 mV closed), low readings mean replace the part
  3. Remove and clean the pilot tube and orifice, a spider web or lint can restrict it
  4. Confirm supply line size meets local code
  5. Verify the spill switch is connected and has continuity with the meter, and if it reads open treat it as a possible venting problem and find out why before going on
  6. Test the valve magnet coil
  7. Work on the gas side belongs to a licensed technician
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Napoleon Gas Fireplace codes

Models

GD70NT-SGD70PT-S

Source: Napoleon (Wolf Steel) Service Manual W415-0118, Part 1-3 Troubleshooting, Pilot Not Holding Flowchart, p.11. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.