Heat & Glo Gas Fireplace: DSI fireplace: ignitor sparks but burner will not light

Updated · by Aurora Star Tech Inc.

DSI fireplace: ignitor sparks but burner will not light on a Heat & Glo gas fireplace: Spark is present but the burner never lights; on RAM 1MC1 modules it sparks for 4 s (-01) or 7 s (-05) then locks out.

Homeowner with a gas fireplace problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: Heat-N-Glo DSI fireplaces: RAM 1MC1-01/-05, RAM-1-RS, Fenwal 24 VAC, CFX-DA, Grand-50-C

Common causes of dsi fireplace: ignitor sparks but burner will not light

  • Gas shut-off closed
  • Air in the gas line
  • Obstruction at the gas valve
  • Burner ports covered by embers
  • Plugged burner orifice
  • Ignitor not over the burner port holes, or sparking at its base
  • No voltage to the gas valve, or failed valve
  • CFX-DA: combustion blower not running or open high-temperature limit

How to fix dsi fireplace: ignitor sparks but burner will not light: step by step

  1. Make sure the gas shut-off is ON and purge air from the line.
  2. Clear any obstruction at the valve, reposition embers off the burner ports and clean the burner orifice.
  3. Adjust the ignitor bracket so the ignitor sits over the port holes; the spark must jump at the tip. A cracked ceramic or spark at the base = replace the ignitor.
  4. 120 VAC modules: switch ON, measure MV to MV RTN on the module, expect 110/120 VAC. Present but valve stays closed = replace the valve; missing = replace the module.
  5. Fenwal 24 V: measure 24 VAC at V1 and V2 on the module. Missing = replace the module; present = replace the valve.
  6. RAM 1MC1 valve wiring: terminal 1 (white) to 3, terminal 2 (blue) to 4.
  7. CFX-DA: the combustion blower must run (it needs outside air via the AK-CFX kit, and the air duct must never elbow down). No 110/120 VAC across MV/MV RTN: check the high-temperature limit, which on this unit is normally closed and must have continuity; blower not running with power at it = replace the blower; blower running but no valve voltage = replace the module.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Heat & Glo Gas Fireplace codes

Models

CFX-DAGrand-50-CRAM-1-RSRAM 1MC1-01RAM 1MC1-05

Source: Heat-N-Glo DSI / HSI Troubleshooting Guide (Professional Development), p.10, 17, 23, 29, 35-36, 43-44. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.