Daikin Water Heater: Route wiring into the tank control board
Route wiring into the tank control board on a Daikin water heater: Power, ground and low-voltage wiring enter through the conduit holes at the bottom of the board. Keep the board and terminal block undamaged.
Applies to: Mega-Q tank control board wiring
How to fix route wiring into the tank control board: step by step
- Route power supply, transmission and sensor relay harness wiring to the tank control board.
- Fit a conduit into the 7/8 in. (22.2 mm) hole at the bottom of the board, for power, ground and low-voltage wiring.
- Protect the wiring with conduit where it passes through holes so the edges cannot damage it.
- Secure the power wiring with the attached clamp so no external force reaches the terminal.
- Seal the gap between the board and the conduit with putty or sealing material to keep small animals out.
If the unit shows an error code, look it up: Daikin Water Heater codes
Source: Mega-Q installation manual, p. 57. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.