Daikin Water Heater: Open the sliding plate in hot-climate regions
Open the sliding plate in hot-climate regions on a Daikin water heater: In hot regions the sliding plate on the heat source unit must be set to OPEN to reduce temperature rise in the main control box. Regions listed in the manual include CA, NV, AZ, NM, OK, TX, AR, LA, MS, AL, TN, GA, NC, SC, FL and Latin America. Failure to do this can cause early component failure.
Applies to: Heat source unit in listed hot-climate regions
How to fix open the sliding plate in hot-climate regions: step by step
- Remove the left screw and loosen the right screw.
- Slide the sliding plate to the right and set the arrow to OPEN.
- Reinstall the left screw and tighten both the left and right screws.
If the unit shows an error code, look it up: Daikin Water Heater codes
More commissioning tips for water heater
Source: Daikin Mega-Q installation manual, p. 10. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.