Daikin Water Heater: Install water temperature sensors on the outer tank wall
Install water temperature sensors on the outer tank wall on a Daikin water heater: Surface-mounted sensors are less accurate and the tape can come loose, so welding a short pipe to the tank is preferred. Accuracy depends on tank wall thickness, so the settings must be checked during trial run and after operation.
Applies to: Mega-Q tank wall-mounted water temperature sensors
Common causes of install water temperature sensors on the outer tank wall
- Tank wall thickness affects reading accuracy
- Aluminum or SUS tape may come off
How to fix install water temperature sensors on the outer tank wall: step by step
- Remove the thermistor cover so the thermistor body can be pulled out (loosen the screw first).
- Cut through the outer jacket and insulation over the sensor spot.
- Attach a short pipe to the surface of the inner tank, preferably by welding.
- Insert the thermistor body into the short pipe.
- Restore the outer jacket and insulation to their original state.
- Protect the thermistor from being dropped, from condensation and from water contact.
If the unit shows an error code, look it up: Daikin Water Heater codes
Source: Mega-Q installation manual, p. 53. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.