Daikin Heat Pump: Unspecified voltage / wrong pair-multi combination, code UA
Unspecified voltage / wrong pair-multi combination, code UA on a Daikin heat pump: The indoor/outdoor transmission signal shows a pair-type unit connected to a multi-type unit, meaning the wrong models are interconnected.
Applies to: Inverter pair wall mounted FTXM-W/V
Common causes of unspecified voltage / wrong pair-multi combination, code ua
- Wrong models interconnected
- Wrong wiring of connecting wires
- Wrong indoor unit PCB or outdoor unit PCB fitted
- Defective indoor unit PCB
- Defective outdoor unit PCB
How to fix unspecified voltage / wrong pair-multi combination, code ua: step by step
- Turn off the power switch before connecting or disconnecting any connector.
- Check that the indoor and outdoor models are compatible.
- If they are not compatible, correct the combination.
- Check the code numbers of the indoor and outdoor PCBs (example format 2P012345) against the Parts List.
- If a PCB does not match, replace it with the correct PCB.
- Check that the connecting wires are connected properly, and correct any wiring error.
- Recheck the indoor and outdoor combination.
If the unit shows an error code, look it up: Daikin Heat Pump codes
Source: Daikin FTXM-W/V service manual SiUS042113EA, p. 115. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.