Warming things up…Dialing in your comfort…Almost cozy…
Reliable Heating and Cooling Solutions – Quality Service, Fair Prices, Guaranteed Satisfaction!

Daikin Heat Pump: Remove the heat exchanger (1.5 to 3.0 ton HP & AC)

Updated · by Aurora Star Tech Inc.

Remove the heat exchanger (1.5 to 3.0 ton HP & AC) on a Daikin heat pump: Access the heat exchanger by removing the suction grille and left side plate, then unbraze it. Protect the area from the flame.

Homeowner with a heat pump problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: 1.5 to 3.0 ton HP & AC

How to fix remove the heat exchanger (1.5 to 3.0 ton hp & ac): step by step

  1. Remove the suction grille (1 screw).
  2. Remove the 4 screws and take off the left side plate.
  3. Remove any putty near the brazed joints first, since it can burn.
  4. Put a protective sheet or steel plate in place so the brazing flame cannot reach nearby parts.
  5. Heat the brazed joints and remove the heat exchanger.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Daikin Heat Pump codes

Source: Daikin SiUS612209EA service instructions, p. 104. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.

Emergency HVAC Service

647-657-2977