Updated · by Aurora Star Tech Inc.

Remove the fan motor and fan (1.5 to 3.0 ton) on a Daikin heat pump: Fan removal sequence. Model-specific differences are noted for 1.5/2.0 ton and 2.5/3.0 ton units.

Homeowner with a heat pump problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: 1.5 to 3.0 ton HP and AC outdoor units

How to fix remove the fan motor and fan (1.5 to 3.0 ton): step by step

  1. Remove the 1 truss head screw and the drip proof cover. Unhook the fan motor lead from the cover.
  2. Cut the clamp and disconnect the fan motor connector X200A.
  3. Remove the fan nut (M8) and remove the fan.
  4. Remove the 2 screws and remove the fan motor stand.
  5. Remove the 4 hex head tapping screws (M5 x 25) and remove the fan motor.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Daikin Heat Pump codes

Source: Daikin SiUS612209EB service instructions, p. 84-86. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.