Daikin Heat Pump: Disconnect the field power and communication wiring and remove the rear plate

Updated · by Aurora Star Tech Inc.

Disconnect the field power and communication wiring and remove the rear plate on a Daikin heat pump: Field wiring is disconnected at the terminal block. The clamps must be cut and the wires disconnected.

Homeowner with a heat pump problem? Call (647) 657-2977 or book a service call — licensed technicians across Vaughan and the GTA.

Applies to: 1.5 to 3.0 ton HP and AC outdoor units

How to fix disconnect the field power and communication wiring and remove the rear plate: step by step

  1. Cut the 2 clamps.
  2. Remove the terminal block screws: 1 pan head M5 x 12 and 2 pan head M4 x 10.
  3. Disconnect the external power supply, ground and communication wires from the terminal block.
  4. Remove the 7 screws and remove the rear plate.
Safety: Gas, electrical and refrigerant work must be done by a licensed technician. Turn off power and gas before servicing, never bypass a safety control, and always follow the manufacturer's manual for your exact model.

If the unit shows an error code, look it up: Daikin Heat Pump codes

Source: Daikin SiUS612209EB service instructions, p. 83. Written in our own words as a summary; always check the original manual.

General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.