Daikin Heat Pump: Disconnect sensors, compressor leads and valve coils (heat pump models)
Disconnect sensors, compressor leads and valve coils (heat pump models) on a Daikin heat pump: Remove the compressor leads, thermistors and valve coils. Cut the clamps as needed and note the clamp and thermistor positions for reassembly.
Applies to: 3.5 to 5.0 ton HP only
How to fix disconnect sensors, compressor leads and valve coils (heat pump models): step by step
- Disconnect the PS connector (X17A).
- Disconnect the compressor connectors (U, V, W) and release the lead wires from the hooks.
- Remove the outdoor air thermistor, outdoor coil thermistor and defrost thermistor.
- Cut the 2 clamps and remove the insulation tube.
- Remove the suction pipe thermistor.
- Cut the 2 clamps on the solenoid valve coil lead wire.
- Remove 2 screws and take off the solenoid valve coil.
- Remove 1 screw and take off the four way valve coil.
- Cut the clamp and pull out the electronic expansion valve coil.
If the unit shows an error code, look it up: Daikin Heat Pump codes
Source: Daikin SiUS612209EA service instructions, pp. 111-112. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.