Daikin Heat Pump: Disconnect HP wiring: PS lead, four-way valve and solenoid valve coils (1.5 to 3.0 ton HP)
Disconnect HP wiring: PS lead, four-way valve and solenoid valve coils (1.5 to 3.0 ton HP) on a Daikin heat pump: Heat pump models only. Disconnect the pressure switch and valve coil leads with the unit powered off.
Applies to: 1.5 to 3.0 ton HP models only
How to fix disconnect hp wiring: ps lead, four-way valve and solenoid valve coils (1.5 to 3.0 ton hp): step by step
- Cut the 4 clamps and disconnect the PS lead at connector X840A.
- When reassembling, fix the lead in the same position with new clamps.
- Cut the 3 clamps and disconnect the four-way valve coil lead at connector X800A.
- Disconnect the solenoid valve coil lead at connector X28A.
- Note the electronic expansion valve coil lead position for reassembly.
If the unit shows an error code, look it up: Daikin Heat Pump codes
Source: Daikin SiUS612209EB service instructions, p. 88. Written in our own words as a summary; always check the original manual.
General guidance for qualified technicians. The manufacturer's installation and service manual and local codes always take priority. Aurora Star Tech is not affiliated with, endorsed by or sponsored by any equipment manufacturer; brand and model names are used only to identify equipment and belong to their owners.